DEAR POLE BARN GURU: Hey Guru! I’m getting ready to build a pole barn and I will have to remove a tree. The tree is basically right in the middle of what the floor will be. I will be putting a concrete floor in and was wondering do I have to completely remove the stump or can I just cut it down below grade and cover it with dirt and gravel? MARK in BROKEN ARROW
DEAR MARK: Completely remove it. You do not want any sort of organic material to remain under a building site. Eventually it will decay, sink and if you have poured a concrete slab over it, the slab could fail any you could find yourself parked in the bottom of a hole in the middle of your barn. Stump removal is relatively inexpensive – and it is something you could probably do yourself along with a properly sized piece of excavation equipment.

 

DEAR POLE BARN GURU: We have a pole building that had a 12’ X 12’ slider door that was recently damaged and needs replaced. Can you point me in the direction I need to go to get a replacement. We wanted to replace it with an overhead door but do not have sufficient clearance for our motorhome. JOYCE in FRANKLIN

DEAR JOYCE: Replacing a sliding door with an overhead door can end up being a near epic challenge as the opening sizes will not be the same. At the very least it will necessitate a custom width overhead door. Before you get too deep into the process, contact three local overhead door companies and ask each to come out to give you a quote on the door. They will be able to tell you what the maximum height is you will be able to get into your building (keeping in mind this may necessitate increasing the height of the door opening). Once this step is done, if you are not already over budget, run an ad on Craigslist under “gigs” best describing the work to be performed – which should include replacement of all of the steel siding on this wall of the building (otherwise it is never going to look right). I have no idea how large your building is, but could easily see this as being a three to five thousand dollar price tag before all is said and done.

Which leads back to – the solution might be to bite the bullet and just replace the sliding door with a new sliding door. You can probably get all of the needed components by a visit to the Pro Desk at your local The Home Depot®.

DEAR POLE BARN GURU: Storage for trailer 35 ft what is a pole distance set with 10 – 12 ft opening? TRACY in NAMPA

DEAR TRACY: I will have to read between the lines here and hope I am able to provide an answer which fits with what your question truly is.

For starters, if I had a 35 foot long trailer to get through a door, I want the opening to be about 12 feet wide. Going 10 feet wide appears to me to be risking some damage.

If the door is to be a sliding door, the space from center of column to center of column on each side of the door should be 12 feet. This will allow the sliding door itself (which should be about 12’2” in width to cover the opening and provide an overlap on each side.

For overhead doors, if getting a residential overhead door, the space BETWEEN the columns should be 12’1”, so as when the 2x jambs are placed on each side of the opening, the finished opening will be 11’10” in width. This will allow the overhead door panels to overlap by an inch on each side. For a commercial overhead door, increase the width between columns by two inches.

 