Building Department Checklist 2020 Part II

Yesterday I covered seven of what I feel are 14 most important questions to ask your local building department.  This not only will smooth your way through permitting processes, but also ensures a solid and safe building structure.

Let’s talk about these last seven….

#8 What is accepted Allowable Soil Bearing Capacity?

This will be a value in psf (pounds per square foot). If in doubt, err to the side of caution. As a rough rule – easier soil to dig, weaker it will be in supporting a building. A new building will only be as solid as it’s foundation, and it’s foundation will be only as strong as soil it rests upon.

Some jurisdictions (most noticeably in California and Colorado) will require a soils (geotechnical) engineer to provide an engineered soil report, spelling out actual tested soil strength.  Other states may have requirements as well, so be sure to ask ahead of time.

#9  Is an engineered soils test required?

If so, get it done ahead of time.  Don’t wait. It’s easy to do and there are plenty of soil (geotechnical) engineers for hire.

#10 What is your Seismic Site Class (such as A, B, C, D, E or F)?

While rarely do potential seismic forces dictate design of a post frame building, there are instances where they can.  A high seismic potential, with high flat roof snow load and low wind load will be one case. Another case will be when you are considering a multiple story structure.

#11 Are wet-stamped engineer signed and sealed structural plans required to acquire a permit?

Some Building Department Officials will say no to this, yet during plans review process they request structural engineering calculations to prove design, or (worse yet) they make wholesale changes to plans, based upon how they think a post frame building should be constructed.

My recommendation – invest in fully engineered plans. It becomes an assurance a registered design professional has verified your building will meet Code mandated loading requirements. In some cases, insurance companies offer discounts for buildings designed by an engineer. It’s certainly worth asking your agent for one!

In some cases, Building Permits will be granted with only requiring engineer sealed truss drawings. We do not condone this practice, as it creates a false sense of security.

Are exterior finished (showing roofing and siding) elevations required with building plans? Will more than two sets of drawings be needed for permit submittal?

#12 Verify Building Risk Category.

Most buildings not frequently occupied by public (not a home, business or municipal building) represent a low hazard to human life in event of a failure and are ASCE (American Society of Civil Engineers) Category I. This information can be found by Building Officials in IBC Table 1604.5 (not to be confused with Use and Occupancy classifications from IBC Chapter 3).

#13 In areas with cold winters, what is your frost depth?

All building columns or foundations must extend below frost line or be adequately perimeter insulated to prevent heave. In some areas, frost depths are as great as 100 inches!

#14 Does the Building Department have any unusual Building Code interpretations, amendments or prescriptive requirements for non-engineered buildings which could affect this building?

If so, get a copy from your building department for us, or anyone else who might be considered to be a provider for your building project.

Even though “the Code is The Code”, there are a plethora of local folks who think they have better ways or better ideas than the world’s smartest structural minds, who have actually written these Codes. And once again, I can’t stress enough: build only from plans sealed by a Registered Design Professional (architect or engineer). It will make life easier all around when it comes to getting your permit, even if you have been told seals are “not required”.

No one inside or outside of a permit office wants a construction process to be any more difficult or challenging than necessary.  Being armed with correct information (after doing homework of course) will be a solid towards your successful building!

2 thoughts on “Building Department Checklist 2020 Part II

  1. I would like to build on existing concrete residential slabs (burnouts).
    My vision is to build two 400 square feet on a 1200 square feet slab using S.I.P.S. panels

    Reply
    1. You should reach out to your local Planning Department, as many jurisdictions will not allow residential units under a certain footprint. You are likely to find SIPs panels to be a very expensive design solution.

      Reply

Leave a Reply

Your email address will not be published. Required fields are marked *