Metal Building Insulation in Pole Building Part II

If you didn’t read my yesterday’s blog – you may want to prior to reading today’s, which is the “rest of the story” on metal building insulation, commonly known as “MBI”.

My first experience installing MBI was not a fun one, in any sense of the word “fun”.

What no one warned us about were safety issues during installation. We should have been advised to wear protective gloves, a dust mask and goggles when working with insulation. Insulation is made of tiny fiberglass shards, which can cause serious irritation of the skin, eyes, nose and throat if you don’t take proper precautions. Instead, we spent several days with red eyes, itching skin and hacking up our lungs!

Now fiberglass itself is not some “magic” insulator, it is the dead air trapped in the uncompressed fiberglass which is doing the work. Smash the air out, and you lose R value. As far as an insulator, every time metal building insulation crosses a framing member, it is compressed to nearly nothing and loses its insulation value. People have this mistaken illusion “thicker must be better”.  Not true. Going to thicker products generally does not really add to the overall heat transfer resistance.

In years since, I’ve had clients tell me how a competitor proposed to insulate their new pole building with R-11 (3-1/2” thick) or even R-19 (6” thick) metal building insulation! First, I would hate to even imagine what the steel would look like, after trying to mash insulation this thick down and screw the metal through the insulation to the roof purlins. It would NOT be pretty. (read yesterday’s blog to see why).  Secondly, there is no way the fiberglass is going to come anywhere close to being able to fully expand between the roof purlins. Keep in mind the “product” does indeed have an R-11 capability (in the case of 3-1/2” thickness), when it is laid out in your driveway. As soon as it gets compressed, R values start to shrink. My educated opinion is a 3-1/2” thick product, in service in a pole building, is probably offering a true R value of between 2 and 4 – just slightly above nothing.

We (Hansen Pole Buildings) now partner with several lumber yard chains, providing pole building kit packages to their clients. Two summers ago I was visiting one of the lumber yard locations in Pennsylvania, in order to provide training to their staff. I went out into their warehouse to greet the store manager. Looking up at the roof of this pole building, I saw tattered MBI hanging down from between the roof purlins and hundreds of birds pecking at the fiberglass, to carry it away for nesting! Any hole in the vinyl at all, and a bird in the building, will result in exactly the same scenario being replayed – much to the chagrin of the poor pole building owner who now has no roof insulation, no condensation control vapor barrier under the roof steel of his building, and nothing but a mess.

In my over 30 years of experience, I can truthfully say I’ve never seen Metal Building insulation look to be a perfect “clean and neat” install product under roof steel.  Moreover, far too often I’ve visited older buildings where the inside view of this product “over time was enough to convince me it was not the optimal choice for pole buildings underneath steel.  Back up a few days to read other blogs where I discuss vapor barrier and reflective radiant barriers.  And stay tuned – for more on other insulation products!

2 thoughts on “Metal Building Insulation in Pole Building Part II

  1. I’m converting a 50′ x 60′ pole building, that was a machine shed on a farm, to a woodworking shop and garage for vehicle repairs and storage. The original building was just a dirt floor. After doing some wind damage repairs, and closing in one gable end of the building where the giant 20×20′ sliding doors were, I’ll be grading and pouring a concrete floor. The building is about 40 years old, and originally had MBI insulation. It has since been tattered by wind and birds, and much of it is gone. I plan on framing in a lower ceiling in both areas. Probably 10′ in the woodshop and 14 in the garage, since I have a lift. Is there any effective way to install a vapor barrier / insulation under the roof metal now? I live in north eastern WA state. Thank you

    Reply
    1. Two realistic choices – as your building is four decades old, I would look at replacing roof steel with new steel having an Integral Condensation control factory applied. Your other choice is to cut out old MBI (not fun or easy) and use two inches of closed cell spray foam applied directly to underside of steel roofing.

      Reply