Lofty Barndominium Ambitions

Lofts and mezzanines (https://www.hansenpolebuildings.com/2020/03/a-mezzanine-for-your-barndominium/) are popular inclusions in barndominiums. Even though my lovely bride and I have a mezzanine in our South Dakota shouse, they are not often truly practical from an accessibility or economics stance.

Reader Devin in Porun writes:

“I’m designing and building a 42’x50′ pole barn home with 10′ exterior walls. Viewing the plans from the front entry on the long wall, the left half of the interior will be framed rooms and the right half will be a large open kitchen/dining/living room space. I want to have an open loft over the half of the building that has interior framing. I want to be able to stand in the loft for at least 3-5′ each side of center, roughly 6′ of head space when finished. What style/type of trusses do you recommend and at what pitch? Would you use the same trusses all the way across the house, or use different ones for each half with the same exterior pitch? I like the high ceilings over the open portion, but would like to minimize the ceiling height to avoid heating and cooling unnecessary space.  Thank you for your time!”


In order to have your greatest possible resale value, you should have any lofted space designed so as to be considered as habitable space. International Residential Code (IRC) Section R304.1 Minimum area. “Habitable rooms shall have a floor area of not less than 70 square feet. R304.2 Minimum dimensions. “Habitable rooms shall be not less than 7 feet in any horizontal dimensions. R304.3 Height effect on room area. “Portions of a room with a sloping ceiling measuring less than 5 feet or a furred ceiling measuring less than 7 feet from the finished floor to the finished ceiling shall not be considered as contributing to the minimum required habitable area for that room.” R305.1 Minimum height. “Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than 7 feet.”

This space will also need to be serviced by stairs, causing you to lose roughly 50 square feet of floor space.

Now, on to trusses – most prefabricated wood truss manufacturers are limited to building and shipping trusses up to 12′ in height. Allowing for truss top chord thickness, on a 42 foot span your maximum roof slope will most often be roughly 6.25/12. You can order “bonus room” trusses for this lofted area, and should be able to get 7’2″ from top of truss bottom chord to bottom of ‘cross tie’ (allowing for thickness of 3/4″ OSB or plywood subflooring and drywall for ceiling to attain a seven foot finished ceiling) in center 10-11 feet, with a maximum room width of roughly 14 feet. These trusses will come along with a healthy cost premium due to larger members required to make this happen and extra shipping costs. In your open portion, you could utilize scissors trusses to reduce heating and cooling as much space, while still giving a spacious cathedral look.

When all is said and done, you might want to consider a more ‘standard’ and economical roof slope of say 4/12 – and add to your ground level footprint rather than trying to gain expensive space in a loft. Keep in mind, this loft space is going to be difficult to move large pieces of furniture (couches, beds, dressers, etc.) in and out of without damage to walls or items being moved and it will prove mobility challenging (or impossible) for a certain population percentage.

A Mezzanine for Your Barndominium

A mezzanine is a common design feature found in all types of buildings- very possibly even your new barndominium, shouse or post frame home. Think of a mezzanine as being a lofted area above a room.

International Building Codes outline some basic rules for mezzanines to help determine if it is an intermediate level within the room it serves or if it is considered another story. 

A mezzanine is an intermediate level between floor and ceiling of any story. In regards to building codes, mezzanines must comply in accordance with IBC (International Building Code) Section 505.2. (Please note all references in this article are 2018 IBC)

Mezzanines can be great features within a building because they provide an additional floor level without being considered an additional story as long as they comply with IBC Section 505.2. Even though they don’t contribute to “building area” or number of “stories” regulated by IBC Section 503.1, they must still be included within “fire area” calculations when determining need for fire protection systems.

Another important piece of information is they should be constructed of consistent materials according to your building’s construction type per IBC Table 601. 

Clear height above and below a mezzanine shall not be less than seven feet.

Total area of a mezzanine within a room shall be not greater than 1/3 floor area of room it is located in (IBC 505.2.1)

Code has some exceptions allowing for a mezzanine to be larger given certain factors such as building’s type of construction and whether the building is equipped with an automatic sprinkler system. IBC 505.2.1 Exception 3 allows for an aggregate area of a mezzanine within a dwelling unit with an approved automatic sprinkler system which can be up to ½ floor area of the room it is located in.

Means of egress (exits) for mezzanines shall comply with applicable provisions of IBC Chapter 10.

A mezzanine acts like a room or space as it has an occupant load. This occupant load must have correct existing parameters per IBC Chapter 10 (egress chapter). IBC Table 1004.5 provides for maximum floor area allowances per occupant. For R-3 (residential) occupancy purposes, this occupant load factor would be 200 square feet per occupant.

A mezzanine shall be open to the room in which it is located, except for walls not more than 42 inches in height.

Code does also provide some exceptions related to mezzanine “openness”. If you meet these exceptions, your mezzanine would not be required to be open. One exception would be if the mezzanine occupant load is not more than 10 (IBC 505.2.3 Exception 1) and another is if it has at least two exits (IBC 505.2.3 Exception 2). In either case you could have an enclosed mezzanine space.

Photos are of the mezzanine within our barndominium. My wife wanted a space within our shouse (shop/house) which would be a totally dedicated space for her sewing and crafts. She has a sign in her sewing loft which clearly states “This is my happy place.” I can tell she is really happy up there as I often can hear her singing along with her favorite rock and roll tunes from the 70’s and 80’s. Lastly, access to her mezzanine is by a wheelchair accessible electric lift system.