This Wednesday the Pole Barn Guru answers reader questions about best way to insulate a vaulted ceiling, truss spacing, and the possibility of adding a small living quarter to a horse barn.

DEAR POLE BARN GURU: With a vaulted ceiling, how do you insulate it if you plan to spray the tin roof with closed cell foam. Was planning on bat insulation on the lower cords of the trusses if needed. what about venting if you spray foam the tin roof? CHRIS in DORCHESTER

DEAR CHRIS: Saline County is located in Climate Zone 5A. As such conditioned buildings require R 60 attic insulation.

You can either:

Have a conditioned attic space – using closed cell spray foam at least two inches thick against underside of roof deck, then adding open cell spray foam or unfaced rock wool batts to get to required R value. This assembly will not be ventilated.

Or

An unconditioned attic. If you have no other method of condensation control, then again place two inches of closed cell spray foam directly to roof steel interior. Vent eaves and ridge, then blow in R 60 of fiberglass across attic. Insulation baffles will need to be placed at eaves to allow for at least an inch of unobstructed air flow above blown in insulation.

 

DEAR POLE BARN GURU: Hello Mike, I have a question regarding a post frame building I would like to build. the size is 40′ x 32′ x 16′ with 6/12 roof pitch. I am planning to use trusses at 2′ foot centers. my question is regarding using 3 tab composition shingles for my roof covering (I have a HOA that will not allow metal roofs), what special considerations might I need to take with respect to where the trusses attach to the top of the post frame wall? the posts will be at 8′ centers and standard girts installed. I was thinking that perhaps increasing the dimensions of the top girt would be necessary. I would appreciate your thoughts on my intentions. I have enjoyed your YouTube videos as well. Sincerely MARK in CODY

Ask The Pole Barn GuruDEAR MARK: Thank you for your kind words about our YouTube videos. https://www.youtube.com/user/HansenBuildings
Personally, I would place double trusses to bear directly upon columns spaced every 10 to 12 feet with purlins on edge, joist hung between truss top chords. This design results in fewest number of holes needing to be dug, as well as fewest pieces of materials to have to install. It also allows for wider door openings.

Doing as you propose, truss carriers (headers between columns to support trusses) would need to be adequately sized by your building’s engineer in order to carry imposed loads without failure or undue deflection.

 

About Hansen BuildingsDEAR POLE BARN GURU: Do you all have barns with living quarters? Not looking for a barndominium, per se, but a restroom with a shower and a living room in addition to 4 stalls and a tack room. we plan on staying there at first while we build the main house on the property, then use for guests or storage. SARAH in SARASOTA

DEAR SARAH: We have provided a plethora of barns with living quarters and every building we provide is custom designed to best meet our client’s wants and needs.

Typically, you should expect to have to two-hour fire separate barn from living area, meaning you cannot go directly from one occupancy to another without going outside in order to do so. For this reason, many of our clients have opted to have a roof only breezeway area between these dissimilar occupancies.

Living Quarters, Plasti-Sleeves, and Poly-carbonate Roof Panels

The Pole Barn Guru answers questions about living quarters, Plasti-Sleeve sizes, and poly-carbonate roof panels.

DEAR POLE BARN GURU: Hello there, 

I have a quick question that I’m hoping someone can answer for me.  For your metal buildings that feature “living quarters” such as (PROJECT# 04-0509), have any of these ever been built on a property in Washington state as the primary residence (not as an accessory building)?

I am searching for a piece of land in Thurston county, and plan to build a home and a ~3,000 square foot shop.  I love the idea of combining the two.  I know that this is common in other parts of the country (with companies like Morton Buildings), I’m just not sure if this is doable in Washington state.

If you have any insight, I’d love to hear it.

Thank you for your time!

ROBERT in OLYMPIA

P.S.  If you have any interior pictures of Project# 04-0509, I would love to see those.

DEAR ROBERT: Thank you for your interest. Post frame (pole) buildings are Code compliant structures and can be erected upon any buildable lot. You will have to meet Washington State Energy requirements Energy Code (as will any new residential construction). Your local Planning Department or a HOA may dictate specific types of roofing and/or siding to meet local covenants. This is not an issue for post frame as we can provide any type of exterior materials.

Because we supply only kit packages, we rarely get finished interior photos of our buildings. We will hope to be seeing ones from you in the not too distant future!

 

DEAR POLE BARN GURU: The pole sleeves are .25″ too small for all of the hem fir PT posts that are used for door openings. What do i do?  SCOTT in EAGLE

DEAR SCOTT:

This is from the manufacturer’s website:

Helpful Hints:

Wood, especially treated, can swell with moisture beyond its normal dimension. If your Plasti-sleeve (more on Plasti-sleeves here: https://www.hansenpolebuildings.com/2012/04/plasti-sleeves/) is too tight, here are some ways to ease installation without forcing it on.

  1. If your post has sharp corners, plane or shave with a saw to allow sleeve to slide on.
  2. Plane or saw sides of the post the length of the Plasti-sleeve.
  3. Use dish soap or similar slippery lubricant to aid in sliding on.
  4. In case of cold weather installation it may help to warm the sleeves to expand them.

 

DEAR POLE BARN GURU: Why do you have the clear (translucent) light panels on the side-wall rather than on the roof?
Thanks, MARK in LAKEVIEW

DEAR MARK: Rather than rehashing a subject I have expounded upon previously, here lies your answer: https://www.hansenpolebuildings.com/2012/01/skylights/.

Challenges also exist with skylights and fires: https://www.hansenpolebuildings.com/2016/01/one-more-reason-to-not-use-skylights-in-steel-roofs/.

 

Towards upper left hand corner of every webpage at www.HansenPoleBuildings.com you will find a magnifying glass adjacent to “Search”. To find information on any post frame building subject CLICK on Search and type your subject into this dropdown box, then ENTER. Magically answers will appear, in order of relevance to your request!

 

Door Facing North, Optimizing Space, and Remodel?

DEAR POLE BARN GURU: I have a (about) 40×24 pole building that faces north. I have a regular door that faces west. The wind and any accompanying rain typically blows directly against that west facing door. The building was built in 1996 by the original owner of the house. I’ve only lived in the house for 3 years and when we bought the house the moulding and threshold were starting to deteriorate. I would like to add an awning over the door to stop the rain from pounding against it. Is it as simple as attaching a ledger board, building off it, and adding a roof? CHRIS in SEAFORD

DEAR CHRIS: You sadly have a very common problem – people all too often end up with exterior people doors which are sadly inadequate for long term use. Most often they have wood jambs which have been left exposed to the weather and not kept painted or otherwise protected.

As to your solution – just adding a roof off the existing building may very well be problematic, as the footings of the existing building are probably inadequate to support the added weight from the added roof (awning).
What I would do – I would replace the troubled entry door with an insulated commercial steel door with steel jambs which is factory finish painted (I actually have recently done this with three of my own doors).
If you do want to build a permanent roof over the door, you should hire a competent registered design professional (architect or engineer) to inspect your present building and design a solution for you which will not compromise the integrity of your existing structure. It will be money well invested.

DEAR POLE BARN GURU: Hello I am wanting to build a 40x104x18 pole barn, my dad will have his living quarters and a wood shop on the main level, the second level will be my living quarters and an exercise room. The top level will be 40’—40 feet. What kind of beam or footing do you recommend? Also if you would like to quote me for this building package that would be great. Thank you, SHAWN in WRIGHT CITY

DEAR SHAWN: Lots of ways you can go with supporting your second floor, and how you design the floor will determine the size (diameter) of the concrete footings needed beneath the individual columns.

Least expensive will place a literal forest of columns below the floor – on 40 foot square, most probably every 10 feet in both directions. Whilst this might be dandy for the pocket book, it could cause challenges with the use of the space below.

As columns become spaced further apart, the beams necessary to support the floor joists and possibly the floor joists themselves are going to become larger in dimension and their cost will not be offset by the savings of a few columns.

I recently designed a floor for a 40 foot by 40 foot residence which had only a single column dead in the center. The LVLs (https://www.hansenpolebuildings.com/2013/01/lvl/) necessary to carry the floor joists were 20 inches in depth! The floor joists were 2×12 at 12 inches on center. Not a low budget investment, but it did provide far greater flexibility downstairs.

Another option is to go to prefabricated wood floor trusses. In our own home we have a 48 foot wide clearspan floor – it is also four feet deep! A floor this thick requires a taller eave height to allow adequate headroom. And yes, it is expensive!

Regardless of which of these options works best for your internal layout it will behoove you to look at the ultimate stiffness of the floor in regards to deflection. Some extended reading on floor deflection and vibration can be found at: https://www.hansenpolebuildings.com/2015/12/wood-floors-deflection-and-vibration/.

DEAR POLE BARN GURU: I currently have a 30×40 pole barn. I want to install a post lift and would need to remove one bottom chord on a truss. The trusses are 4ft on center. Is this possible and how would I do such a thing? The pole barn is also insulated and closed in with 5/8 osb. Except for the one 8 ft span. DUSTIN in NESCOPECK

DUSTIN: Given enough time and money, anything is possible, although probably not practical. Your situation is one of my “case in points” as to why post frame buildings with trusses placed every four feet on top of truss carriers is not the most flexible design solution when it comes to having to remodel.

Should you pursue a remodel, it should ultimately involve a registered design professional (architect or engineer) as what you are looking at doing is not going to be a simple task.

I’d probably follow a path such as this – adding a new extra truss to the single truss at each side of the eight foot area. Temporarily supporting the flat purlins over the middle truss whilst removing it, then adding purlins on edge between the two new trusses (and either under or next to the existing purlins). Keep in mind, this is a highly simplistic outline and the actual fix will be far more complicated.

A less expensive solution – add a 12 foot bay onto one end of the building with a truss on each side of the 12 feet and purlins spanning from truss to truss.